The Exam module has many examination equipment interfaces available that eliminate the need for double data-entry and reduce errors. Insight Software, LLC is a certified Marco partner. For more information on Exam setup, refer to the Exams Setup section. For pricing information please visit our website at http://www.myvisionexpress.com/licensing_options.htm.
|
Table 3 - Equipment Interfaces Available for My Vision Express | |||
|
Company |
Equipment |
Integration |
Information |
|
Marco |
❶ RT-2100 (TRS-2100 or EPIC 2100), RT-5100 (EPIC 5100), or RT-900 (Evolution) and one or a combination of the following: ❶ LM-500 Lensmeter ❶ LM-600 Lensmeter ❶ LM-1000 Lensmeter* ❶ LM-1200 Lensmeter* ❶ Spectrum (VL-3000) Lensmeter ❶ AR-20 Autorefractor ❶ ARK-30 Autorefractor/Keratometer* ❶ ARK 510A Autorefractor/Keratometer* ❶ ARK-530A Autorefractor/Keratometer* ❶ ARK-560A Autorefractor/Keratometer* ❶ ARK-700A Autorefractor/Keratometer* ❶ ARK-730A Autorefractor/Keratometer* ❶ ARK-760A Autorefractor/Keratometer* ❶ 3-D Wave (ARK-10000) Autorefractor/Keratometer ❶ RKT-7700 (M3) Autorefractor/Keratometer/ Non-Contact Tonometer* ❶ Tonoref-2 Autorefractor/Keratometer/ Non-Contact Tonometer * ❶ NT-500 Tonometer ❶ NT-2000 Tonometer |
All of the equipment is integrated with Marco Connect Software |
The equipment listed in bold in the "Equipment" column is required for the My Vision Express equipment integration The equipment listed with an asterisk (*) will interface with My Vision Express without a Marco digital refraction system. The equipment listed with an asterisk (❶ ) will interface with My Vision Express Web Hosted Solution
|
|
Carl Zeiss Meditech, Inc |
❶ HARK-599 Autorefractor/Keratometer* ❶ LA-350 and LA-360 (Humphrey) Lens Analyzer* Stratus OCT 6.0** Cirrus OCT 4.0** Visante OCT 3.0** HFA II-i 4.2.2** Atlas 9000 3.0** IOL Master 5.4** Visucam 4.1 & 4.2** FF450 &Visupac 4.3 & 4.4.1**
|
The equipment listed with an asterisk (*) will be a Direct Integration with My Vision Express
The equipment listed with two asterisk (**) will be interface with FORUM 2.0. For more information about FORUM 2.0, please contact Zeiss Meditech. |
The equipment listed with an asterisk (❶ ) will interface with My Vision Express Web Hosted Solution |
|
Carl Zeiss Vision |
i.Terminal |
Direct Integration with all equipment listed |
The iTerminal requires Miro Client Software |
|
Oculus |
Keratograph Twinfield Centerfield Synoptometer Anomaloscope Binoptometer Binoptometer 3 Mesotest ImageCam Easyfield EasyGraph Pentacam C-Quant PeriVision |
Integration with Oculus Software |
The Oculus software will only run in a 32-bit Windows Operating System. |
|
Tomey - USA |
RT-7000* |
The equipment listed with an asterisk (*) will be interface with Tomey-USA DataTransfer software |
|
|
HAAG-STREIT |
Octopus 123* Octopus 300 Basic* Octopus 300 Pro* Octopus 301* Octopus 311* Octopus 900* |
The equipment listed with an asterisk (*) will be a interface with HAAG-STREIT Eye Suite |
|
|
Lombart |
DVS System 8.0 |
Will be a connection with the DVS System 8.0 Software |
|
|
Topcon Medical Systems |
❶ CV-5000 Digital Refractor, CV-3000 Digital Refractor, or CV-2500 Digital Refractor and one or a combination of the following: ❶ CL-100 Lensmeter* ❶ CL-200 Lensmeter* ❶ CT-80 Tonometer* ❶ KR-7000 Autorefractor/Keratometer* ❶ KR-7000P Autorefractor/Keratometer* ❶ KR-8000 Autorefractor/Keratometer* ❶ KR-8000PA Autorefractor/Keratometer* ❶ KR-8800 Autorefractor/Keratometer* ❶ RM-7000 Autorefractor* ❶ RM-8000 Autorefractor* ❶ RM-8800 Autorefractor* SOFTWARE IMAGEnet 2000 & IMAGEnet Lite |
All equipment is integrated Directly. The KR-8000PA is integrated Directly or thru Topcon Color Mapping Software. |
The equipment listed in bold in the "Equipment" column is required for the My Vision Express equipment integration. The equipment listed with an asterisk (*) will interface with My Vision Express without a Topcon digital refraction system. The equipment listed with an asterisk (❶ ) will interface with My Vision Express Web Hosted Solution IMAGEnet 2000/Lite: You must install IMAGEnet 2000 and IMAGEnet 2000 Lite software before you can use the integration with My Vision Express. Contact a Topcon representative for more details. |
|
Table 3 - Equipment Interfaces Available for My Vision Express (Continued) | |||
|
Company |
Equipment |
Integration |
Information |
|
EyeRoute by Topcon |
Images will only be available for the following equipment: Accutome A-Scan Bausch & Lomb Orbscan Clarity RetCam COAS HD Wavefront Analyzer Digital Healthcare Oculab Escalon/MRP Ophthalvision Heidelberg HRA2 Heidelberg HRTII, HRT3 I3 Ultrasound Nidek MP1 Nidek Confocal Nidek 3DX Nidek NonMyd Oculus Easyfield OIS Winstation Optikon Keratron Optos Optomap OTI OCT/SLO OTI Ultrasound Quantel Ultrasound Sonomed Ultrasound Talia RTA Topcon ImageNet Veris ERG Visx WaveScan Eximer Laser Zeiss Stratus OCTIII |
Direct Integration with EyeRoute.
|
EyeRoute is a Web-based image management solution; images can be accessed from a single web-based user interface. The software is fully HIPAA compliant and meets the highest network security requirements with high-end firewall protection.
|
|
TelScreen |
SOFTWARE EyeRes 2000 |
|
|
|
Huvitz |
CDR-3100 Digital Refractor, or HDR-7000 Digital Refractor, and one or a combination of the following: MRK-3100P Autorefractor/Keratometer HRK-7000 Autorefractor/Keratometer HRK-7000A Autorefractor/Keratometer CLM-3100P Autolensmeter CLM-4000 Autolensmeter HLM-7000 Autolensmeter |
All of the equipment is integrated with CDRMate or HDRMate Software |
The equipment listed in bold in the "Equipment" column is required for the My Vision Express equipment integration
The equipment listed with an asterisk (*) will interface with My Vision Express without a Huvitz digital refraction system.
The equipment listed with an asterisk (*) will interface with My Vision Express Web Hosted Solution |
Equipment interfaces must be setup first before they can be used to capture the readings.
The setup equipment interfaces:
Select File > Setup > Exam > Equipment Interface… to open the Exam Equipment Integration screen and click Import to open the Equipment screen.
58. 
NOTE: If you do not have a valid activation code, consult an Insight Software, LLC employee.

Click to highlight the appropriate Device and click Select to start the process to capture the readings from the device. If you do not want to import the device, click Close to return to the Exam Equipment Integration screen.